Fault Code Diagnostics
42
133 85 Short circuit to positive of the rail select
position sensor
When submitting a warranty claim under standard
warranty conditions, the complete TCU should be
replaced and the entire unit submitted with warranty
claim.
Out-of-warranty only and/or no warranty claim
submitted, replace the sensor or replace the lower part
of the TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
134 86 Short circuit to ground of the rail select
position sensor
When submitting a warranty claim under standard
warranty conditions, the complete TCU should be
replaced and the entire unit submitted with warranty
claim.
Out-of-warranty only and/or no warranty claim
submitted, replace the sensor or replace the lower part
of the TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
135 87 Open circuit of the rail select position
sensor
When submitting a warranty claim under standard
warranty conditions, the complete TCU should be
replaced and the entire unit submitted with warranty
claim.
Out-of-warranty only and/or no warranty claim
submitted, replace the sensor or replace the lower part
of the TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
136 88 Gate select sensor self-adjustment error If the TCU has not just been installed, complete the
pneumatic requirements flowchart.
If the TCU has just been installed, the gate selector
actuator did not correctly engage into the rail. Using
TransSoft, verify that the gate selector position sensor
counts are outside of the nominal range: 70 to 120 or
500 to 580. If so, remove the TCU and reinstall it.
137 89 No range change group sensor signal
(short circuit to positive)
When submitting a warranty claim under standard
warranty conditions, the complete TCU should be
replaced and the entire unit submitted with warranty
claim.
Out-of-warranty only and/or no warranty claim
submitted, replace the sensor or replace the lower part
of the TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
138 8A No range change group sensor signal
(short circuit to ground)
When submitting a warranty claim under standard
warranty conditions, the complete TCU should be
replaced and the entire unit submitted with warranty
claim.
Out-of-warranty only and/or no warranty claim
submitted, replace the sensor or replace the lower part
of the TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
ISO Fault Code Diagnostics
NOTE: ISO display codes may not be available on vehicles built prior to January 2006.
ISO Fault
Identifier
ISO Display
Fault Codes
(J587 Display) Fault Description
Repair Instructions
NOTE: The following repair instructions pertain to
active faults only. For information and instructions
about inactive faults, please contact OnTrac at
866-668-7221 and request a transmission
specialist.