Fault Code Diagnostics
44
145 91 Range shift disengagement error Complete the pneumatic requirements flowchart.
If no issues are found with the air system, contact
OnTrac at 866-668-7221 and request a ZF-FreedomLine
transmission specialist.
146 92 Range shift changeover error Complete the pneumatic requirements flowchart.
The range actuator did not correctly engage into the rail.
Using TransSoft, verify that the range position sensor
counts are outside of the nominal range: 80 to 130 or 490
to 590. The measured values should not drift or show
signal disturbances after range shifting. Values outside
range, exchange main transmission. If error occurs
sporadically: When submitting a warranty claim under
standard warranty conditions, the complete TCU should
be replaced and the entire unit submitted with warranty
claim. Out-of-warranty only and/or no warranty claim
submitted, replace the lower part of TCU.
For assistance contact OnTrac at 866-668-7221 and ask
for a transmission specialist.
147 93 Range shift engagement error Complete the pneumatic requirements flowchart.
The range actuator did not correctly engage into the rail.
Using TransSoft, verify that the range position sensor
counts are outside of the nominal range: 80 to 130 or
490 to 590. The measured values should not drift or
show signal disturbances after range shifting. Values
outside range, exchange main transmission. If error
occurs sporadically: When submitting a warranty claim
under standard warranty conditions, the complete TCU
should be replaced and the entire unit submitted with
warranty claim. Out-of-warranty only and/or no
warranty claim submitted, replace the lower part of
TCU.
For assistance contact OnTrac at 866-668-7221 and ask
for a transmission specialist.
148 94 Splitter selection fault; splitter cylinder
does not disengage
Complete the pneumatic requirements flowchart.
The splitter group does not leave the previous position
within defined time. Using TransSoft, verify that the
splitter position sensor counts are outside of the nominal
range: 70 to 140 or 500 to 620.
The measured values should not drift or show signal
disturbances after splitter shifting. Values outside range,
exchange main transmission. If error occurs
sporadically: When submitting a warranty claim under
standard warranty conditions, the complete TCU should
be replaced and the entire unit submitted with warranty
claim.
Out-of-warranty only and/or no warranty claim
submitted, replace the lower part of TCU.
For assistance, contact OnTrac at 866-668-7221 and ask
for a transmission specialist.
ISO Fault Code Diagnostics
NOTE: ISO display codes may not be available on vehicles built prior to January 2006.
ISO Fault
Identifier
ISO Display
Fault Codes
(J587 Display) Fault Description
Repair Instructions
NOTE: The following repair instructions pertain to
active faults only. For information and instructions
about inactive faults, please contact OnTrac at
866-668-7221 and request a transmission
specialist.
Page view 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 191 192

Comments to this Manuals

No comments