Section 3
Maintenance
91
PTO Requirements Flowchart
Notice
The ZF-FreedomLine transmission is delivered pre-programmed to accept both a stationary PTO (for use in
neutral) and a non-stationary PTO (for use in the default PTO gear only). The installation of the PTO is the
responsibility of the owner. An improperly installed PTO may damage the transmission gearing, requiring
a transmission replacement.
The Transmission Controller Unit (TCU) actively monitors the PTO and acts accordingly. Pin A of the PTO
connector must be wired into the PTO switch. Pin C of the PTO connector must be wired into the series of
relays that activate the PTO. Pin B of the PTO connector must be wired into the ball switch that
acknowledges the engagement of the PTO.
4005005b
Is the voltage
in spec?
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Replace the
wire harness.
Is the
resistance in
spec?
Using a
Volt-Ohm meter,
check for 9.0 to 16.0 VDC
on pin B of the
transmission side of
the PTO connector.
Using a Volt-Ohm
meter, check for
9.0 to 16.0 VDC
on pin C of the
transmission side of
the PTO connector.
Using a Volt-Ohm meter, check
for 9.0 to 16.0 VDC on pin A of
the transmission side of
the PTO connector.
Using a Volt-Ohm meter, check
for continuity (0.0 to 0.5 ohms)
between pin A of the PTO
connector, J9, and pin G1
of the ZMTEC connector, J3.
Using a Volt-Ohm meter, check
for continuity (0.0 to 0.5 ohms)
between pin B of the PTO
connector, J9, and pin G2
of the ZMTEC connector, J3.
Using a Volt-Ohm meter, check
for continuity (0.0 to 0.5 ohms)
between pin C of the PTO
connector, J9, and pin B1
of the ZMTEC connector, J3.
Replace the
wire harness.
Replace the
ZMTEC.
Replace the
wire harness.
Replace the
ZMTEC.
Replace the
ZMTEC.
Is the voltage
in spec?
Is the voltage
in spec?
Is the
resistance in
spec?
Is the
resistance in
spec?
Is the voltage
in spec?
Is the voltage
in spec?
Is the voltage
in spec?
Using a Volt-Ohm meter,
check that the voltage at
pin A of the PTO connector, J9,
drops to 0.0 to 0.5 VDC
when the circuit is grounded.
Replace the
ZMTEC.
Replace the
ZMTEC.
Replace the
ZMTEC.
Using a Volt-Ohm meter,
check that the voltage at
pin B of the PTO connector, J9,
drops to 0.0 to 0.5 VDC
when the circuit is grounded.
Using a Volt-Ohm meter,
check that the voltage at
pin C of the PTO connector, J9,
drops to 0.0 to 0.5 VDC
when the circuit is grounded.
The transmission is
functioning properly.
Contact Muncie at
(800) FOR PTOS or
(800) 367-7867 for
diagnostic assistance.