Section 2
Fault Code Diagnostics
18
50 5 SID 32 Open circuit at the output stage to
the rail select #2 solenoid (Y5)
When submitting a warranty claim under
standard warranty conditions, the complete TCU
should be replaced and the entire unit submitted
with warranty claim. Out-of-warranty only
and/or no warranty claim submitted, replace
lower part of TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
50 6 SID 32 Short circuit to ground at the output
stage to the rail select #2 solenoid
(Y5)
When submitting a warranty claim under
standard warranty conditions, the complete TCU
should be replaced and the entire unit submitted
with warranty claim. Out-of-warranty only
and/or no warranty claim submitted, replace
lower part of TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
51 3 SID 33 Short circuit to positive at the output
stage to the gear engage #2
solenoid (Y7)
When submitting a warranty claim under
standard warranty conditions, the complete TCU
should be replaced and the entire unit submitted
with warranty claim. Out-of-warranty only
and/or no warranty claim submitted, replace
lower part of TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
51 5 SID 33 Open circuit at the output stage to
the gear engage #2 solenoid (Y7)
When submitting a warranty claim under
standard warranty conditions, the complete TCU
should be replaced and the entire unit submitted
with warranty claim. Out-of-warranty only
and/or no warranty claim submitted, replace
lower part of TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
51 6 SID 33 Short circuit to ground at the output
stage to the gear engage #2
solenoid (Y7)
When submitting a warranty claim under standard
warranty conditions, the complete TCU should be
replaced and the entire unit submitted with warranty
claim. Out-of-warranty only and/or no warranty claim
submitted, replace lower part of TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
54 3 SID 36 Short circuit to positive at the output
stage to the inertia brake solenoid
(Y1)
When submitting a warranty claim under standard
warranty conditions, the complete TCU should be
replaced and the entire unit submitted with warranty
claim. Out-of-warranty only and/or no warranty claim
submitted, replace lower part of TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
54 5 SID 36 Open circuit at the output stage to
the inertia brake solenoid (Y1)
When submitting a warranty claim under standard
warranty conditions, the complete TCU should be
replaced and the entire unit submitted with warranty
claim. Out-of-warranty only and/or no warranty claim
submitted, replace lower part of TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
SAE Fault Code Repair Instructions
SAE J1587 Fault
Code
Instrument
Panel
Display
Fault Code Fault Description
Repair Instructions
NOTE: The following repair instructions pertain
to active faults only. For information and
instructions about inactive faults, please
contact OnTrac at 866-668-7221 and request a
transmission specialist.Fault FMI
PID/
SID
Page view 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 191 192

Comments to this Manuals

No comments